| htop - PressureStallMeter.c |
| (C) 2004-2011 Hisham H. Muhammad |
| (C) 2019 Ran Benita |
| Released under the GNU GPLv2+, see the COPYING file |
| in the source distribution for its full text. |
| */ |
| |
| #include "config.h" // IWYU pragma: keep |
| |
| #include "linux/PressureStallMeter.h" |
| |
| #include <stdbool.h> |
| #include <string.h> |
| |
| #include "CRT.h" |
| #include "Meter.h" |
| #include "Object.h" |
| #include "Platform.h" |
| #include "RichString.h" |
| #include "XUtils.h" |
| |
| |
| static const int PressureStallMeter_attributes[] = { |
| PRESSURE_STALL_TEN, |
| PRESSURE_STALL_SIXTY, |
| PRESSURE_STALL_THREEHUNDRED |
| }; |
| |
| static void PressureStallMeter_updateValues(Meter* this) { |
| const char* file; |
| if (strstr(Meter_name(this), "CPU")) { |
| file = "cpu"; |
| } else if (strstr(Meter_name(this), "IO")) { |
| file = "io"; |
| } else if (strstr(Meter_name(this), "IRQ")) { |
| file = "irq"; |
| } else { |
| file = "memory"; |
| } |
| |
| bool some; |
| if (strstr(Meter_name(this), "Some")) { |
| some = true; |
| } else { |
| some = false; |
| } |
| |
| Platform_getPressureStall(file, some, &this->values[0], &this->values[1], &this->values[2]); |
| |
| /* only print bar for ten (not sixty and threehundred), cause the sum is meaningless */ |
| this->curItems = 1; |
| |
| xSnprintf(this->txtBuffer, sizeof(this->txtBuffer), "%s %s %5.2lf%% %5.2lf%% %5.2lf%%", some ? "some" : "full", file, this->values[0], this->values[1], this->values[2]); |
| } |
| |
| static void PressureStallMeter_display(const Object* cast, RichString* out) { |
| const Meter* this = (const Meter*)cast; |
| char buffer[20]; |
| int len; |
| |
| len = xSnprintf(buffer, sizeof(buffer), "%5.2lf%% ", this->values[0]); |
| RichString_appendnAscii(out, CRT_colors[PRESSURE_STALL_TEN], buffer, len); |
| len = xSnprintf(buffer, sizeof(buffer), "%5.2lf%% ", this->values[1]); |
| RichString_appendnAscii(out, CRT_colors[PRESSURE_STALL_SIXTY], buffer, len); |
| len = xSnprintf(buffer, sizeof(buffer), "%5.2lf%% ", this->values[2]); |
| RichString_appendnAscii(out, CRT_colors[PRESSURE_STALL_THREEHUNDRED], buffer, len); |
| } |
| |
| const MeterClass PressureStallCPUSomeMeter_class = { |
| .super = { |
| .extends = Class(Meter), |
| .delete = Meter_delete, |
| .display = PressureStallMeter_display, |
| }, |
| .updateValues = PressureStallMeter_updateValues, |
| .defaultMode = TEXT_METERMODE, |
| .maxItems = 3, |
| .total = 100.0, |
| .attributes = PressureStallMeter_attributes, |
| .name = "PressureStallCPUSome", |
| .uiName = "PSI some CPU", |
| .caption = "PSI some CPU: ", |
| .description = "Pressure Stall Information, some cpu" |
| }; |
| |
| const MeterClass PressureStallIOSomeMeter_class = { |
| .super = { |
| .extends = Class(Meter), |
| .delete = Meter_delete, |
| .display = PressureStallMeter_display, |
| }, |
| .updateValues = PressureStallMeter_updateValues, |
| .defaultMode = TEXT_METERMODE, |
| .maxItems = 3, |
| .total = 100.0, |
| .attributes = PressureStallMeter_attributes, |
| .name = "PressureStallIOSome", |
| .uiName = "PSI some IO", |
| .caption = "PSI some IO: ", |
| .description = "Pressure Stall Information, some io" |
| }; |
| |
| const MeterClass PressureStallIOFullMeter_class = { |
| .super = { |
| .extends = Class(Meter), |
| .delete = Meter_delete, |
| .display = PressureStallMeter_display, |
| }, |
| .updateValues = PressureStallMeter_updateValues, |
| .defaultMode = TEXT_METERMODE, |
| .maxItems = 3, |
| .total = 100.0, |
| .attributes = PressureStallMeter_attributes, |
| .name = "PressureStallIOFull", |
| .uiName = "PSI full IO", |
| .caption = "PSI full IO: ", |
| .description = "Pressure Stall Information, full io" |
| }; |
| |
| const MeterClass PressureStallIRQFullMeter_class = { |
| .super = { |
| .extends = Class(Meter), |
| .delete = Meter_delete, |
| .display = PressureStallMeter_display, |
| }, |
| .updateValues = PressureStallMeter_updateValues, |
| .defaultMode = TEXT_METERMODE, |
| .maxItems = 3, |
| .total = 100.0, |
| .attributes = PressureStallMeter_attributes, |
| .name = "PressureStallIRQFull", |
| .uiName = "PSI full IRQ", |
| .caption = "PSI full IRQ: ", |
| .description = "Pressure Stall Information, full irq" |
| }; |
| |
| const MeterClass PressureStallMemorySomeMeter_class = { |
| .super = { |
| .extends = Class(Meter), |
| .delete = Meter_delete, |
| .display = PressureStallMeter_display, |
| }, |
| .updateValues = PressureStallMeter_updateValues, |
| .defaultMode = TEXT_METERMODE, |
| .maxItems = 3, |
| .total = 100.0, |
| .attributes = PressureStallMeter_attributes, |
| .name = "PressureStallMemorySome", |
| .uiName = "PSI some memory", |
| .caption = "PSI some memory: ", |
| .description = "Pressure Stall Information, some memory" |
| }; |
| |
| const MeterClass PressureStallMemoryFullMeter_class = { |
| .super = { |
| .extends = Class(Meter), |
| .delete = Meter_delete, |
| .display = PressureStallMeter_display, |
| }, |
| .updateValues = PressureStallMeter_updateValues, |
| .defaultMode = TEXT_METERMODE, |
| .maxItems = 3, |
| .total = 100.0, |
| .attributes = PressureStallMeter_attributes, |
| .name = "PressureStallMemoryFull", |
| .uiName = "PSI full memory", |
| .caption = "PSI full memory: ", |
| .description = "Pressure Stall Information, full memory" |
| }; |